LOG-IN  
E-mail  
 
Password  
 
 
  Forgot password?  
Rules and laws
  Click on one of the voices of the below index and you will be able to visualize the complete text of the law or norm that you have selected.
   
 
EN 60081 EN 60188 EN 60192
EN 60357 EN 60432-1 EN 60432-2
EN 60598-1 EN 60598-2-1 EN 60598-2-2
EN 60598-2-4 EN 60598-2-6 EN 60662
EN 60901 EN 60968 EN 60969
EN 61167 EN 61195 EN 61199
EN 62035 EN 60064    
   
EN 60081
Double-capped fluorescent lamps - Performance specifications

Gives technical requirements for tubular fluorescent lamps with preheated cathodes for general lighting service, operated with or without a starter from a.c. mains, also describes tests for the lamps with non-preheated cathodes operated without the use of a starter. Gives testing methods to be used for checking quality and interchangeability for type testing, for individual lamp batches or for a manufacturer's entire production. Consists of a series of standard data sheets, each giving the characteristics of a specific lamp type. Introduces new co-ordinates for the standard colours together with a new standard 'white' colour.
  top
EN 60188
High-pressure mercury vapour lamps

Specifies methods of test for electrical and luminous characteristics for lamps with or without a red correcting fluorescent coating as well as a method of measurement of the red ratio.
  top
EN 60192
Low-pressure sodium vapour lamps

States the methods of test to be used for determining the characteristics of low pressure sodium vapour lamps of the integral type, both U-shaped and linear, operating on a.c. mains, 50 Hz or 60 Hz.
  top
EN 60357
Tungsten halogen lamps (non-vehicle)

Specifies dimensions and characteristics of tungsten halogen lamps, designed specifically for the following applications: projection, photographic (including studio), flood lighting, specialized airfield purpose and general purpose.
  top
EN 60432-1
Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes

Specifies the safety and interchangeability requirements of tungsten filament incandescent lamps for general lighting service, having a rated wattage up to and including 200 W or a rated voltage from 50 V to 250 V inclusive.
  top
EN 60432-2
Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes.

Specifies the safety and the related interchangeability requirements of tungsten halogen lamps for general lighting service. Covers those tungsten halogen lamps that are used as direct replacements for conventional tungsten filament lamps as well as new tungsten halogen lamps which have no correspondence in EN 60432-1, but for which the safety and interchangeability requirements are treated by this standard in conjunction with EN 60432-1.
  top
EN 60598-1
Luminaires - Part 1: General requirements and tests

Covers general requirements for the classification and marking of luminaires and for their mechanical and electrical construction, together with related tests. Is applicable to luminaires for use with tungsten filaments, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1000 V.
  top
EN 60598-2-1
Luminaires - Part 2: Particular requirements - Section 1: Fixed general purpose luminaires

Specifies requirements for fixed general purpose luminaires for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1000 V.
  top
EN 60598-2-2
Luminaires - Part 2: Particular requirements - Section 2: Recessed luminaires

Specifies requirements for recessed luminaires for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltage not exceeding 1000 V.
  top
EN 60598-2-4
Luminaires - Part 2: Particular requirements - Section 4: Portable general purpose luminaires

Specifies requirements for portable general purpose luminaires, other than handlamps, for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 250 V.
  top
EN 60598-2-6
Luminaires - Part 2: Particular requirements - Section 6: Luminaires with built-in transformers for filament lamps

Specifies requirements for luminaires with built-in transformers for filament lamps, with supply voltages and output voltages not exceeding:
1000 V for class I and class II luminaires and
250 V for class 0 luminaires.
  top
EN 60662
High-pressure sodium vapour lamps

Specifies the lamp dimensions, electrical characteristics for lamp starting and operation together with information for ballast, ignitor and luminaire design purposes.
  top
EN 60901
Single-capped fluorescent lamps - Performance specifications

Specifies the performance requirements for single-capped fluorescent lamps for general lighting service.
The requirements of this standard relate only to type testing. Conditions of compliance, including methods of statistical assessment, are under consideration.
  top
EN 60968
Self-ballasted lamps for general lighting services - Safety requirements

Specifies the safety and interchangeability requirements, together with the test methods and conditions, required to show compliance of tubular fluorescent and other gas-discharge lamps with integrated means for controlling starting and stable operation (self-ballasted lamps), intended for domestic and similar general lighting purposes, having: -a rated wattage up to 60 W; -a rated voltage of 100 V to 250 V; -Edison screw or bayonet caps.
  top
EN 60969
Self-ballasted lamps for general lighting services - Performance requirements

Specifies the performance requirements together with the test methods and conditions required to show compliance of tubular fluorescent and other gas-discharge lamps with integrated means for controlling starting and stable operation (self-ballasted lamps), intended for domestic and similar general lighting purposes.
  top
EN 61167
Glow-starters for fluorescent lamps

Specifies interchangeable starters used with pre-heat type tubular fluorescent lamps and should be used in conjunction with corresponding publications for fluorescent lamps and their ballasts.
  top
CEI EN 61195
Double-capped fluorescent lamps - Safety specifications

Specifies the safety requirements for double-capped fluorescent lamps for general lighting purposes of all groups having Fa6, Fa8, G5, G13 and R17d caps. Also specifies the method a manufacturer should use to show compliance with the requirements of this standard.
  top
EN 61199
Single-capped fluorescent lamps - Safety specifications

Specifies the safety requirements for single-capped fluorescent lamps for general lighting purposes of all groups having 2G7, 2GX7, GR8, G10q, GR10q, GX10q, GY10q, 2G11, G23, GX23, G24, GX32 and 2G13 caps. Also specifies the method a manufacturer should use to show compliance with the requirements of this standard.
  top
EN 62035
Discharge lamps (excluding fluorescent lamps) - Safety specifications

Specifies the safety requirements for discharge lamps (excluding fluorescent lamps) for general lighting purposes.
This International Standard is applicable to low-pressure sodium vapour lamps and to high-intensity discharge (HID) lamps, i.e. high-pressure mercury vapour lamps (including blended lamps), high-pressure sodium vapour lamps and metal halide lamps. It applies to single- and double-capped lamps.
  top
EN 60064
Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements

Applies to tungsten filament incandescent lamps for general lighting services which comply with the safety requirements in EN 60432-1.
  top