 |
 |
Rules and laws |
|
| |
Click on one of the
voices of the below index and you will be able to visualize
the complete text of the law or norm that you have selected.
|
| |
|
 |
 |
| |
|
 |
 |
| |
|
 |
EN 60081
Double-capped fluorescent lamps -
Performance specifications
Gives technical requirements
for tubular fluorescent lamps with preheated cathodes
for general lighting service, operated with or without
a starter from a.c. mains, also describes tests for
the lamps with non-preheated cathodes operated without
the use of a starter. Gives testing methods to be used
for checking quality and interchangeability for type
testing, for individual lamp batches or for a manufacturer's
entire production. Consists of a series of standard
data sheets, each giving the characteristics of a specific
lamp type. Introduces new co-ordinates for the standard
colours together with a new standard 'white' colour.
|
| |
top
 |
 |
EN 60188
High-pressure mercury vapour lamps
Specifies methods of test
for electrical and luminous characteristics for lamps
with or without a red correcting fluorescent coating
as well as a method of measurement of the red ratio. |
| |
top
 |
 |
EN 60192
Low-pressure sodium vapour lamps
States the methods of test
to be used for determining the characteristics of low
pressure sodium vapour lamps of the integral type, both
U-shaped and linear, operating on a.c. mains, 50 Hz
or 60 Hz. |
| |
top
 |
 |
EN 60357
Tungsten halogen lamps (non-vehicle)
Specifies dimensions
and characteristics of tungsten halogen lamps, designed
specifically for the following applications: projection,
photographic (including studio), flood lighting, specialized
airfield purpose and general purpose. |
| |
top
 |
 |
EN 60432-1
Incandescent lamps - Safety specifications
- Part 1: Tungsten filament lamps for domestic and similar
general lighting purposes
Specifies the safety and interchangeability
requirements of tungsten filament incandescent lamps
for general lighting service, having a rated wattage
up to and including 200 W or a rated voltage from 50
V to 250 V inclusive. |
| |
top
 |
 |
EN 60432-2
Incandescent lamps - Safety specifications
- Part 2: Tungsten halogen lamps for domestic and similar
general lighting purposes.
Specifies the safety and the
related interchangeability requirements of tungsten
halogen lamps for general lighting service. Covers those
tungsten halogen lamps that are used as direct replacements
for conventional tungsten filament lamps as well as
new tungsten halogen lamps which have no correspondence
in EN 60432-1, but for which the safety and interchangeability
requirements are treated by this standard in conjunction
with EN 60432-1. |
| |
top
 |
 |
EN 60598-1
Luminaires - Part 1: General requirements
and tests
Covers general requirements
for the classification and marking of luminaires and
for their mechanical and electrical construction, together
with related tests. Is applicable to luminaires for
use with tungsten filaments, tubular fluorescent and
other discharge lamps on supply voltages not exceeding
1000 V. |
| |
top
 |
 |
EN 60598-2-1
Luminaires - Part 2: Particular requirements
- Section 1: Fixed general purpose luminaires
Specifies requirements for
fixed general purpose luminaires for use with tungsten
filament, tubular fluorescent and other discharge lamps
on supply voltages not exceeding 1000 V. |
| |
top
 |
 |
EN 60598-2-2
Luminaires - Part 2: Particular requirements
- Section 2: Recessed luminaires
Specifies requirements
for recessed luminaires for use with tungsten filament,
tubular fluorescent and other discharge lamps on supply
voltage not exceeding 1000 V. |
| |
top
 |
 |
EN 60598-2-4
Luminaires - Part 2: Particular requirements
- Section 4: Portable general purpose luminaires
Specifies requirements
for portable general purpose luminaires, other than
handlamps, for use with tungsten filament, tubular fluorescent
and other discharge lamps on supply voltages not exceeding
250 V. |
| |
top
 |
 |
EN 60598-2-6
Luminaires - Part 2: Particular requirements
- Section 6: Luminaires with built-in transformers for
filament lamps
Specifies requirements
for luminaires with built-in transformers for filament
lamps, with supply voltages and output voltages not
exceeding:
1000 V for class I and class II luminaires and
250 V for class 0 luminaires. |
| |
top
 |
 |
EN 60662
High-pressure sodium vapour lamps
Specifies the lamp
dimensions, electrical characteristics for lamp starting
and operation together with information for ballast,
ignitor and luminaire design purposes. |
| |
top
 |
 |
EN 60901
Single-capped fluorescent lamps -
Performance specifications
Specifies the performance
requirements for single-capped fluorescent lamps for
general lighting service.
The requirements of this standard relate only to type
testing. Conditions of compliance, including methods
of statistical assessment, are under consideration. |
| |
top
 |
 |
EN 60968
Self-ballasted lamps for general
lighting services - Safety requirements
Specifies the safety
and interchangeability requirements, together with the
test methods and conditions, required to show compliance
of tubular fluorescent and other gas-discharge lamps
with integrated means for controlling starting and stable
operation (self-ballasted lamps), intended for domestic
and similar general lighting purposes, having: -a rated
wattage up to 60 W; -a rated voltage of 100 V to 250
V; -Edison screw or bayonet caps. |
| |
top
 |
 |
EN 60969
Self-ballasted lamps for general
lighting services - Performance requirements
Specifies the performance
requirements together with the test methods and conditions
required to show compliance of tubular fluorescent and
other gas-discharge lamps with integrated means for
controlling starting and stable operation (self-ballasted
lamps), intended for domestic and similar general lighting
purposes. |
| |
top
 |
 |
EN 61167
Glow-starters for fluorescent lamps
Specifies interchangeable
starters used with pre-heat type tubular fluorescent
lamps and should be used in conjunction with corresponding
publications for fluorescent lamps and their ballasts.
|
| |
top
 |
 |
CEI EN 61195
Double-capped fluorescent lamps -
Safety specifications
Specifies the safety
requirements for double-capped fluorescent lamps for
general lighting purposes of all groups having Fa6,
Fa8, G5, G13 and R17d caps. Also specifies the method
a manufacturer should use to show compliance with the
requirements of this standard. |
| |
top
 |
 |
EN 61199
Single-capped fluorescent lamps -
Safety specifications
Specifies the safety
requirements for single-capped fluorescent lamps for
general lighting purposes of all groups having 2G7,
2GX7, GR8, G10q, GR10q, GX10q, GY10q, 2G11, G23, GX23,
G24, GX32 and 2G13 caps. Also specifies the method a
manufacturer should use to show compliance with the
requirements of this standard. |
| |
top
 |
 |
EN 62035
Discharge lamps (excluding fluorescent
lamps) - Safety specifications
Specifies the safety requirements
for discharge lamps (excluding fluorescent lamps) for
general lighting purposes.
This International Standard is applicable to low-pressure
sodium vapour lamps and to high-intensity discharge
(HID) lamps, i.e. high-pressure mercury vapour lamps
(including blended lamps), high-pressure sodium vapour
lamps and metal halide lamps. It applies to single-
and double-capped lamps. |
| |
top
 |
 |
EN 60064
Tungsten filament lamps for domestic
and similar general lighting purposes - Performance
requirements
Applies to tungsten filament incandescent lamps for
general lighting services which comply with the safety
requirements in EN 60432-1. |
| |
top
 |